Bellow is a table of the index of refraction of a few liquids that may be useful index matching in an experiment. The measurement of the refractive index was measured using an ATAGO PAL-RI handheld refractometer. Uncertainties reflect measurement uncertainties and are not indications of batch to batch variations in these off the shelf products.

 Temperature during measurement [C]Index of refraction [-]
Windex Original (with ammonia-D)25.4 ± 0.1
1.3322 ± 0.0004
Water25.0 ± 0.11.3325 ± 0.0002
Vinegar, White Distilled 26.7 ± 0.11.3350 ± 0.0002
Dawn Ultra26.6 ± 0.25
1.3758 ± 0.0002
Micro-90 concentrated cleaner 25.9 ± 0.25
1.4082 ± 0.0002
Paraffin Lamp Oil (Lamplight Ultra-Pure) 27.1 ± 0.11.4276 ± 0.0002
Lamp Oil (Florasense brand) 24.6 ± 0.11.4389 ± 0.0002
Mineral Oil, Baby oil (Johnson's brand)27.6 ± 0.11.4634 ± 0.0002
Glycerin (99 %)27.8 ± 0.11.4718 ± 0.0002
Mineral Oil (Kroger brand)27.7 ± 0.11.4729 ± 0.0002
Safflower Oil (Gamblin brand) 24 ± 0.51.4746 ± 0.0002
Linseed Oil, Refined (Winsor & Newton brand)25.4 ± 0.11.4754 ± 0.0002
Linseed Oil, Purified (Daler Rowney brand) 27 ± 11.4789 ± 0.0002
Mineral Oil (equate brand)26.5 ± 0.25
1.4798 ± 0.0002
3-IN-ONE oil27.5 ± 0.11.4877 ± 0.0002